Max CVSS 10.0 Min CVSS 4.0 Total Count2
IDCVSSSummaryLast (major) updatePublished
CVE-2017-14011 6.8
A Cross-Site Request Forgery issue was discovered in ProMinent MultiFLEX M10a Controller web interface. The application does not sufficiently verify requests, making it susceptible to cross-site request forgery. This may allow an attacker to execute
09-10-2019 - 23:23 17-10-2017 - 22:29
CVE-2017-14007 6.8
An Insufficient Session Expiration issue was discovered in ProMinent MultiFLEX M10a Controller web interface. The user's session is available for an extended period beyond the last activity, allowing an attacker to reuse an old session for authorizat
09-10-2019 - 23:23 17-10-2017 - 22:29
CVE-2017-14009 4.0
An Information Exposure issue was discovered in ProMinent MultiFLEX M10a Controller web interface. When an authenticated user uses the Change Password feature on the application, the current password for the user is specified in plaintext. This may a
09-10-2019 - 23:23 17-10-2017 - 22:29
CVE-2017-14005 6.5
An Unverified Password Change issue was discovered in ProMinent MultiFLEX M10a Controller web interface. When setting a new password for a user, the application does not require the user to know the original password. An attacker who is authenticated
09-10-2019 - 23:23 17-10-2017 - 22:29
CVE-2017-14013 6.8
A Client-Side Enforcement of Server-Side Security issue was discovered in ProMinent MultiFLEX M10a Controller web interface. The log out function in the application removes the user's session only on the client side. This may allow an attacker to byp
09-10-2019 - 23:23 17-10-2017 - 22:29
CVE-2017-12718 6.8
A Classic Buffer Overflow issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. A third-party component used in the pump does not verify input buffer size prior to copying, leading to a buffe
09-10-2019 - 23:23 15-02-2018 - 10:29
CVE-2017-10622 10.0
An authentication bypass vulnerability in Juniper Networks Junos Space Network Management Platform may allow a remote unauthenticated network based attacker to login as any privileged user. This issue only affects Junos Space Network Management Platf
09-10-2019 - 23:21 13-10-2017 - 17:29
CVE-2017-10612 6.0
A persistent site scripting vulnerability in Juniper Networks Junos Space allows users who can change certain configuration to implant malicious Javascript or HTML which may be used to steal information or perform actions as other Junos Space users o
09-10-2019 - 23:21 13-10-2017 - 17:29
CVE-2017-10624 5.1
Insufficient verification of node certificates in Juniper Networks Junos Space may allow a man-in-the-middle type of attacker to make unauthorized modifications to Space database or add nodes. Affected releases are Juniper Networks Junos Space all ve
09-10-2019 - 23:21 13-10-2017 - 17:29
CVE-2017-5701 4.4
Insecure platform configuration in system firmware for Intel NUC7i3BNK, NUC7i3BNH, NUC7i5BNK, NUC7i5BNH, NUC7i7BNH versions BN0049 and below allows an attacker with physical presence to run arbitrary code via unauthorized firmware modification during
03-10-2019 - 00:03 11-10-2017 - 00:29
CVE-2003-0909 7.2
Windows XP allows local users to execute arbitrary programs by creating a task at an elevated privilege level through the eventtriggers.exe command-line tool or the Task Scheduler service, aka "Windows Management Vulnerability."
12-10-2018 - 21:33 01-06-2004 - 04:00
CVE-2017-12722 5.0
An Out-of-bounds Read issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. A third-party component used in the pump reads memory out of bounds, causing the communications module to crash. Sm
02-03-2018 - 16:09 15-02-2018 - 10:29
CVE-2017-13723 4.6
In X.Org Server (aka xserver and xorg-server) before 1.19.4, a local attacker authenticated to the X server could overflow a global buffer, causing crashes of the X server or potentially other problems by injecting large or malformed XKB related atom
04-02-2018 - 02:29 10-10-2017 - 01:30
CVE-2017-13999 7.5
A Stack-based Buffer Overflow issue was discovered in WECON LEVI Studio HMI Editor v1.8.1 and prior. Multiple stack-based buffer overflow vulnerabilities have been identified in which the application does not verify string size before copying to memo
13-01-2018 - 02:29 17-10-2017 - 22:29
CVE-2017-14353 6.8
A remote code execution vulnerability in HP UCMDB Foundation Software versions 10.10, 10.11, 10.20, 10.21, 10.22, 10.30, 10.31, 10.32, and 10.33, could be remotely exploited to allow code execution.
11-11-2017 - 02:29 05-10-2017 - 15:29
CVE-2017-14354 4.3
A remote cross-site scripting vulnerability in HP UCMDB Foundation Software versions 10.10, 10.11, 10.20, 10.21, 10.22, 10.30, 10.31, 10.32, and 10.33 could be remotely exploited to allow cross-site scripting.
11-11-2017 - 02:29 05-10-2017 - 15:29
Back to Top Mark selected
Back to Top