Max CVSS | 7.5 | Min CVSS | 4.3 | Total Count | 2 |
ID | CVSS | Summary | Last (major) update | Published | |
CVE-2019-7225 | 5.8 |
The ABB HMI components implement hidden administrative accounts that are used during the provisioning phase of the HMI interface. These credentials allow the provisioning tool "Panel Builder 600" to flash a new interface and Tags (MODBUS coils) mappi
|
16-05-2023 - 11:15 | 27-06-2019 - 17:15 | |
CVE-2018-20846 | 4.3 |
Out-of-bounds accesses in the functions pi_next_lrcp, pi_next_rlcp, pi_next_rpcl, pi_next_pcrl, pi_next_rpcl, and pi_next_cprl in openmj2/pi.c in OpenJPEG through 2.3.0 allow remote attackers to cause a denial of service (application crash).
|
27-02-2023 - 16:48 | 26-06-2019 - 18:15 | |
CVE-2018-20845 | 4.3 |
Division-by-zero vulnerabilities in the functions pi_next_pcrl, pi_next_cprl, and pi_next_rpcl in openmj2/pi.c in OpenJPEG through 2.3.0 allow remote attackers to cause a denial of service (application crash).
|
27-02-2023 - 16:48 | 26-06-2019 - 18:15 | |
CVE-2018-20847 | 6.8 |
An improper computation of p_tx0, p_tx1, p_ty0 and p_ty1 in the function opj_get_encoding_parameters in openjp2/pi.c in OpenJPEG through 2.3.0 can lead to an integer overflow.
|
27-02-2023 - 16:47 | 26-06-2019 - 18:15 | |
CVE-2019-12751 | 7.5 |
Symantec Messaging Gateway, prior to 10.7.1, may be susceptible to a privilege escalation vulnerability, which is a type of issue whereby an attacker may attempt to compromise the software application to gain elevated access to resources that are nor
|
24-08-2020 - 17:37 | 11-07-2019 - 21:15 | |
CVE-2019-10964 | 5.8 |
In Medtronic MinMed 508 and Medtronic Minimed Paradigm Insulin Pumps, Versions, MiniMed 508 pump – All versions, MiniMed Paradigm 511 pump – All versions, MiniMed Paradigm 512/712 pumps – All versions, MiniMed Paradigm 712E pump–All versions, MiniMed
|
24-08-2020 - 17:37 | 28-06-2019 - 21:15 | |
CVE-2019-10995 | 5.8 |
ABB CP651 HMI products revision BSP UN30 v1.76 and prior implement hidden administrative accounts that are used during the provisioning phase of the HMI interface.
|
24-01-2020 - 13:53 | 14-01-2020 - 17:15 | |
CVE-2019-10979 | 7.5 |
SICK MSC800 all versions prior to Version 4.0, the affected firmware versions contain a hard-coded customer account password.
|
01-08-2019 - 13:15 | 01-07-2019 - 21:15 | |
CVE-2004-0685 | 4.6 |
Certain USB drivers in the Linux 2.4 kernel use the copy_to_user function on uninitialized structures, which could allow local users to obtain sensitive information by reading memory that was not cleared from previous usage.
|
11-10-2017 - 01:29 | 23-12-2004 - 05:00 |