Max CVSS 10.0 Min CVSS 1.9 Total Count2
IDCVSSSummaryLast (major) updatePublished
CVE-2003-1307 4.3
The mod_php module for the Apache HTTP Server allows local users with write access to PHP scripts to send signals to the server's process group and use the server's file descriptors, as demonstrated by sending a STOP signal, then intercepting incomin
21-03-2024 - 02:13 31-12-2003 - 05:00
CVE-2016-7466 1.9
Memory leak in the usb_xhci_exit function in hw/usb/hcd-xhci.c in QEMU (aka Quick Emulator), when the xhci uses msix, allows local guest OS administrators to cause a denial of service (memory consumption and possibly QEMU process crash) by repeatedly
12-02-2023 - 23:25 10-12-2016 - 00:59
CVE-2017-9445 5.0
In systemd through 233, certain sizes passed to dns_packet_new in systemd-resolved can cause it to allocate a buffer that's too small. A malicious DNS server can exploit this via a response with a specially crafted TCP payload to trick systemd-resolv
31-01-2022 - 18:19 28-06-2017 - 06:29
CVE-2016-7415 7.5
Stack-based buffer overflow in the Locale class in common/locid.cpp in International Components for Unicode (ICU) through 57.1 for C/C++ allows remote attackers to cause a denial of service (application crash) or possibly have unspecified other impac
23-04-2019 - 19:29 17-09-2016 - 21:59
CVE-2006-4017 4.3
Cross-site scripting (XSS) vulnerability in the search module in Inter Network Marketing (INM) CMS G3 allows remote attackers to inject arbitrary web script or HTML via the search_string parameter.
17-10-2018 - 21:32 07-08-2006 - 19:04
CVE-2014-5394 4.3
Multiple Huawei Campus switches allow remote attackers to enumerate usernames via vectors involving use of SSH by the maintenance terminal.
29-01-2018 - 19:03 08-01-2018 - 19:29
CVE-2008-2559 7.5
Integer overflow in Borland Interbase 2007 SP2 (8.1.0.256) allows remote attackers to execute arbitrary code via a malformed packet to TCP port 3050, which triggers a stack-based buffer overflow. NOTE: this issue might be related to CVE-2008-0467.
08-08-2017 - 01:31 05-06-2008 - 22:32
CVE-2016-0917 7.5
The SMB service in EMC VNXe (VNXe3200 Operating Environment prior to 3.1.5.8711957 and VNXe3100/3150/3300 Operating Environment prior to 2.4.4.22638), VNX1 File OE before 7.1.80.3, VNX2 File OE before 8.1.9.155, and Celerra (all supported versions) d
30-07-2017 - 01:29 21-09-2016 - 02:59
CVE-2016-0925 3.5
Cross-site scripting (XSS) vulnerability in the Case Management application in EMC RSA Adaptive Authentication (On-Premise) before 6.0.2.1.SP3.P4 HF210, 7.0.x and 7.1.x before 7.1.0.0.SP0.P6 HF50, and 7.2.x before 7.2.0.0.SP0.P0 HF20 allows remote au
30-07-2017 - 01:29 21-09-2016 - 02:59
CVE-2016-0903 6.4
Avamar Data Store (ADS) and Avamar Virtual Edition (AVE) in EMC Avamar Server before 7.3.0-233 rely on client-side authentication, which allows remote attackers to spoof clients and read backup data via a modified client agent.
30-07-2017 - 01:29 21-09-2016 - 02:59
CVE-2016-0904 5.0
Avamar Data Store (ADS) and Avamar Virtual Edition (AVE) in EMC Avamar Server before 7.3.0-233 use the same encryption key across different customers' installations, which allows remote attackers to defeat cryptographic protection mechanisms and obta
30-07-2017 - 01:29 21-09-2016 - 02:59
CVE-2017-5167 7.5
An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. Users do not have any option to change their own passwords.
28-06-2017 - 13:53 13-02-2017 - 21:59
CVE-2017-5166 5.0
An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. An INFORMATION EXPOSURE flaw can be used to gain privileged access to the device.
16-02-2017 - 16:13 13-02-2017 - 21:59
CVE-2017-5165 6.8
An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. There is no CSRF Token generated per page and/or per (sensitive) function. Successful exploitation of this vulnerability can allow silent execution of unauthori
16-02-2017 - 16:11 13-02-2017 - 21:59
CVE-2017-5162 10.0
An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. Lack of authentication for remote service gives access to application set up and configuration.
16-02-2017 - 16:09 13-02-2017 - 21:59
CVE-2017-5164 4.3
An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. Input sent from a malicious client is not properly verified by the server. An attacker can execute arbitrary script code in another user's browser session (CROS
16-02-2017 - 16:08 13-02-2017 - 21:59
CVE-2016-0930 5.0
Pivotal Cloud Foundry (PCF) Ops Manager before 1.6.19 and 1.7.x before 1.7.10, when vCloud or vSphere is used, has a default password for compilation VMs, which allows remote attackers to obtain SSH access by connecting within an installation-time pe
28-11-2016 - 19:56 18-09-2016 - 02:59